SCARA, 6-Axis and Modules
Technical Support Notes

Article ID: T50
Date: 4/24/2000
Product: SPEL for Windows 1.x (all versions)
OS: Windows 98
Problem: Internal error 5 during first Jog and Teach open on Windows 98

Symptoms
Using SPEL for Windows 1.x, when the Jog and Teach dialog is open for the first time, an internal error 5 occurs.  After clicking OK, the Jog and Teach dialog will open.

Causes
Due to changes in the Windows 98 operating system from previous systems, SPEL for Windows 1.x software does not run properly.   Other problems also occur.  For example, after Jog and Teach is open, the point files in the controller are updated every time, even though they don't need to be.  

Remedies
Windows 98 is not supported for SPEL for Windows 1.x software.  It is strongly recommended that you upgrade to version 2.x 32 bit software.  The 1.x versions are 16 bit and were designed for use on Windows 3.1.   You can also use 1.x versions on Windows 95 and Windows NT 4.0, but again, the upgrade to 2.0 is strongly recommended. 

Currently, Windows NT 4.0 is the preferred operating system to use with SPEL for Windows.

Click here to return to the EPSON Robots home page
The Power of Choice!