Vision Guide 2.x (all
versions up to and including 2.2.2)
OS:
Windows NT 4.0
Problem:
Hang up during program
reformat
Symptoms After making changes in the Vision Guide window without
saving, clicking on another child window title bar will cause continuous
"Reformatting programs" message on the status bar and the software
hangs.
Causes
Steps to Repeat:
1. Open a program window.
2. Open Vision Guide.
3. Change a vision object.
4. Click on the program window title
bar.
5. You will see the "Reformatting
programs" message continuously displayed on the status bar.
Remedies There are two workarounds for this problem:
1. After making changes in Vision Guide,
save the changes before clicking on another window. One easy way to save
changes is to click the Save button on the tool bar.
2. Avoid clicking on a child window title
bar to activate the window. Click in the text area.
Status This problem has been fixed in version 2.2.3.