SCARA, 6-Axis and Modules
Technical Support Notes

Article ID: T1105
Date: 7/21/05
Product: EPSON RC+ v4.1.0, v4.1.0 SP1
Subject: Brake release problem with Cont after safeguard closed

Symptoms
Sometimes if Cont is executed immediately after the safeguard is closed, such as in an SGClose trap or by remote, all brakes are released before motor power is restored.  Or in some cases, a torque error will occur.

Important:  This problem can cause one or more joints to fall depending on the robot model and mounting orientation.

Causes
This is caused by a bug in EPSON RC+ versions 4.1.0 and 4.1.0 SP1. 

Remedy
To workaround the problem, add a one second delay before executing Cont after the safeguard is closed.

Status
This problem was fixed in version 4.1.0 SP2.

 

Click here to return to the EPSON Robots home page
The Power of Choice!