| Article ID: | T1073 |
| Date: | 7/10/02 (updated 10/3/02) |
| Product: | EPSON RC+ (all versions before 3.5.0) |
| Subject: | Vision Guide calibrations not saved if more than 13 are created |
Symptoms
If more than 13 vision camera calibrations are created in
the same project, the calibration data from 14 on is not saved.
Causes
This is
caused by a bug in EPSON RC+.
Remedy
Keep the number of calibrations less than
14.
Status
This problem was fixed in version 3.5.0.