SCARA, 6-Axis and Modules
Technical Support Notes

Article ID: T1073
Date: 7/10/02 (updated 10/3/02)
Product: EPSON RC+  (all versions before 3.5.0)
Subject: Vision Guide calibrations not saved if more than 13 are created

Symptoms
If more than 13 vision camera calibrations are created in the same project, the calibration data from 14 on is not saved.

Causes
This is caused by a bug in EPSON RC+.

Remedy
Keep the number of calibrations less than 14.

Status
This problem was fixed in version 3.5.0.

Click here to return to the EPSON Robots home page