Epson RC620+ Fieldbus I/O

Fieldbus I/O

  • Supports Industry Standard Fieldbus I/O Systems
  • Support for DeviceNet, EtherNet/IP, Profibus, CC-Link
  • Master or Slave Devices Available
  • Fully Integrated into EPSON RC+ Development Environment

Fieldbus I/O is used in factories worldwide to reduce cabling costs, setup time, and promote standard device usage. However, there is not 1 accepted Fieldbus I/O standard. Instead there are quite a few different ones. The more commonly used Fieldbus I/O standards are: DeviceNet, Profibus, EtherNet/IP and CC-Link. The EPSON RC620+ Controller supports all 4 of these Fieldbus I/O options. Normally companies will standardize on one Fieldbus I/O communications protocol and use devices for that protocol throughout their factories. Therefore, EPSON doesn't push or promote 1 protocol over any of the others but instead supports all 4 so we can give our customers the power of choice to select the Fieldbus I/O solution standard used in their factory.

Some of the more common reasons factories use fieldbus I/O as opposed to normal discrete I/O solutions are shown below:

  • Access to signals from multiple devices and multiple data from each device using one cable
  • Precise signal transmission since there is no need for A/D conversion and D/A conversion.
  • Less wiring costs, including signal relay board costs and installation area due to several dozen (or a hundred) devices connected on one fieldbus
  • More flexible modification and expansion of a system because multiple devices are simply added to one Fieldbus without additional wiring

Epson RC620+ Fieldbus I/O

Features & Benefits

EPSON supports all 4 of the major Fieldbus I/O standards including: DeviceNet, EtherNet/IP, Profibus, and CC-Link. The RC620+ Controller has option slots available for these cards and our EPSON RC+ Software is fully integrated to support each of the Fieldbus I/O standards quickly and easily.

High Performance

  • Fieldbus I/O processing is done on the Fieldbus I/O cards
  • Fast communication throughput is part of the reason to use Fieldbus I/O
  • DeviceNet, Profibus and EtherNet/IP are all available as Master or Slave solutions
  • Tight Integration with EPSON RC+ Ensures fastest throughput

Ease of Use Leader

  • Full support for all 4 major Fieldbus I/O Standards
  • GUI based setup for configuring I/O mapping, etc
  • Full Integration with EPSON RC+ and the SPEL+ Language makes I/O access easy
  • Works with all Epson Robots supported by the RC620+ Controller

Most Popular in the Following Industries

  • Automotive
  • Medical
  • Consumer Products
  • Industrial
  • Telecommunications
  • Semiconductor
  • Electronics

Epson RC620+ Fieldbus I/O

Specifications

DeviceNet

Master Support: Yes
Slave Device Support: Yes
Slave Device Max I/O: 2040 Inputs / 2040 Outputs
Master Device Max I/O: 1024 Inputs / 1024 Outputs
Connection Types: I/O Messaging & Explicit Messaging
I/O Messaging Types: Polling, Strobe, Change of State, Cyclic
Maximum Nodes: 64 (including master unit)
Baud Rates: 125Kbps, 250Kbps, 500Kbps
Data Length/Frame: 8 byte
Transfer Distance: 500Kbps/10M, 250Kbps/250M, 125Kbps/500M
Cable Type: 5 wire cable dedicated to DeviceNet
Communications Power Supply: 24VDC

EtherNet/IP

Master Support: Yes
Slave Device Support: Yes
Slave Device Max I/O: 4040 Inputs / 4072 Outputs
Master Device Max I/O: 1024 Inputs / 1024 Outputs
Connection Types: I/O Messaging & Explicit Messaging
I/O Messaging Types: Change of State, Cyclic
Maximum Nodes: 128 (including master unit)
Baud Rates: 100Mbps, 10Mbps
Data Length/Frame: 244 byte
Cable Type: Universal Ethernet Cable
 

Profibus

Master Support: Yes
Slave Device Support: Yes
Slave Device Max I/O: 1952 Inputs / 1952 Outputs
Master Device Max I/O: 1024 Inputs / 1024 Outputs
Connection Method: Hybrid (token passing procedure)
Maximum Stations: 126 (including master and repeater)
Baud Rates: 9.6Kbps to 12Mbps
Data Length/Frame: 244 bytes
Transfer Distance: 12Mbps/100M, 9.6Kbps/1200M
Cable Type: 2 wire cable dedicated to Profibus

CC-Link

Master Support: NO
Slave Device Support: Yes
Connection Method: broadcast Polling
Synchronization Method: Frame Synchronization
Maximum Nodes: 64 slave stations (including master unit)
Baud Rates: 156Kbps, 10Mbps
Transmission Channel Type: Bus (EAI RS-485 compliant)
Transmission Format: HDLC compliant
Cable Type: CC-Link Ver 1.1 Cable (3 core twist with shield)
 

 

Epson RC620+ Fieldbus I/O

Options & Accessories


Sorry, this product currently has no accessories. Please check back soon!

Epson RC620+ Fieldbus I/O

Downloads